Strip Light Driver

15W Strip Light Driver
(CT0G120125)

SPECIFICATION

INPUT REQUIREMENTS

INPUT OPERATING VOLTAGE
140VAC - 270VAC
INPUT FREQUENCY
47Hz - 53Hz
INRUSH CURRENT
< 25A peak @ 230VAC Cold start @ 25º C.
INPUT CURRENT
< 500mA rms @ 140 VAC.
EFFICIENCY
> 80% typical at 230VAC Input full load.

OUTPUT CHARACTERISTIC:

OUTPUT VOLTAGE
12.0VDC
OUTPUT CURRENT
1.25A
LINE & LOAD REGULATION
± 5%.
RIPPLE
< 120mV. Pk - Pk, at Nominal Input.
NOISE
< 240mV. Pk - Pk, at Nominal Input (measured with 0.1µF ceramic disc & 10µF Electrolytic capacitor across output in 20 MHz bandwidth oscilloscope.)
OUTPUT OVER CURRENT
> 1.50A < 2.00Amp ( from 140VAC Input - 270VAC )

PROTECTIONS:

OUTPUT OVERLOAD / SHORT CIRCUIT PROTECTION
Available
PROTECTION AGAINST CONTROL CKT. FAILURE
Available
INPUT OVER VOLTAGE / PROTECTION
Available
OVER TEMPERATURE PROTECTION
Available

ENVIRONMENT

TEMPERATURE
Operation Ambient 0ºC to + 50ºC ambient.
Storage -15ºC to + 70ºC ambient.
HUMIDITY
Operating 5% RH to 95% RH non-condensing.
Storage 5% RH to 95% RH non-condensing.

PRODUCT SAFETY:

DI-ELECTRIC VOLTAGE WITHSTAND TEST
3KVAC rms, 50Hz for one minute (trip current set at 5mA). Between Shorted INPUT and Shorted OUTPUT Terminals.
INSULATION RESISTANCE
When tested with a 500VDC Megger shall be > 100 M ohms Between Shorted INPUT and Shorted OUTPUT Terminals.

RELIABILITY & QUALITY

COMPONENT DERATING FACTORS
All Semiconductors Junction Temperature Shall not Exceeded the Manufacturer’s Maximum Thermal Rating.

EMI / EMC

SURGE IMMUNITY
As per Test standard IEC61000 - 4 - 5
Test Level 3: +/- 2KV in Differential Mode
ELECTRICAL FASTTRANSIENTS
As per Test standard IEC61000 - 4 - 4
Test Level 3: 2KV
ESD
As per Test standard IEC61000 - 4 - 2
Test Level 3: Air discharge : 8KV
Test Level 3: Contact Discharge : 6KV

TERMINATIONS:

AC Input
AC 2core Blue and Brown 160mm Length, cable other end directly solder to PCB.
DC Output
DC 2core Grey and Black 160mm Length, cable other end directly solder to PCB.